Busch-Jaeger 2CKA006134A0324

Busch-Jaeger 2CKA006134A0324 handleiding

(1)
  • G
    F
    D
    E
    A B C
    1
    2
    L
    N
    16A
    KNX
    230 V
    L
    N
    KNX
    24 V DC
    1a 1b 1c 1d 2 3
    A B
    1
    4
    A BCD
    EFGH
    IJK
    A
    (3)
    Pos: 2 /F alt blatt 35x42/ 00_F B-Kopf/F B-K öpfe i n A nleitung en/6 128 - - Dec kblatt r echts - - EAC @ 43\m od_14 39796 1397 06_0.doc x @ 374092 @ @ 1
    6128/28-xxx
    0073-1-8773 / 14.08.2015
    www.busch-jaeger-katalog.de/
    6134-0-0321,artikel.html
    === Ende der Liste für Textmarke Titel ===
    Pos: 4 /Faltblatt 35x42/KNX/Installationsbus/6128/6128 @ 43\mod_1438424178138_1.docx @ 370922 @ 11222222222 @ 1
    Deutsch
    Busch-Installationsbus
    ®
    KNX,
    Busch-Powernet
    ®
    KNX
    Bedienelement 2/4-fach mit
    Raumtemperaturregler
    GEFAHR
    Bei direktem oder indirektem Kontakt mit spannungs-
    führenden Teilen kommt es zu einer gefährlichen
    Körperdurchströmung. Elektrischer Schock,
    Verbrennungen oder der Tod können die Folge sein. Bei
    unsachgemäß ausgeführten Arbeiten an
    spannungsführenden Teilen besteht Brandgefahr.
    Vor Montage und Demontage Netzspannung
    freischalten!
    Arbeiten am 230 V-Netz nur von Fachpersonal
    ausführen lassen.
    Montageanleitung sorgfältig lesen und aufbewahren.
    Weitere Benutzerinformationen und Informationen für die
    Parametrierung und Inbetriebnahme unter www.BUSCH-
    JAEGER.de oder durch Scannen des QR-Codes.
    Bestimmungsgemäßer Gebrauch
    Der Raumtemperaturregler ist zur Steuerung eines
    Ventilatorkonvektors mit Fan Coil-Aktor oder konventionellen
    Heizungs- und Kühlinstallationen geeignet.
    Für die Bedienelemente stehen umfangreiche Funktionen zur
    Verfügung. Den Applikationsumfang entnehmen Sie bitte dem
    Technischen Handbuch (DE, EN, FR, IT, NL, ES) zum Produkt.
    Technische Daten
    Versorgung
    Busankoppler: 24 V DC (erfolgt über Buslinie)
    Netzankoppler: 230 V AC / 50 Hz
    Busteilnehmer: maximal 12 mA
    KNX-Anschluss:
    Busankoppler: Busanschlussklemme, schraubenlos
    Netzankoppler: Schraubklemmen am UP-Einsatz
    Temperaturbereich: -5 °C … +45 °C
    Schutzart: IP20
    Lagertemperatur: -20 °C … +70 °C
    Weitere Merkmale
    Diebstahlschutz
    Tag-/Nachtumschaltung der LEDs
    Beschriftbar
    Montage
    [1a …d]
    Die Montage darf nur auf einem separat zu bestellenden Bus-/
    Netzankoppler UP in trockenen Innenräumen erfolgen. Dabei die
    geltenden Vorschriften beachten.
    Montagehinweise beachten.
    Abdeckrahmen separat bestellen.
    [2] Die Wippen besitzen einen Verdrehschutz (unterer Steg breiter),
    damit die Wippen richtig herum aufgesteckt werden.
    [3] Das Schutzschild des Beschriftungsfeldes lässt sich abnehmen.
    Beachten Sie für das Einsetzen die obige Abbildung.
    Anschluss
    Anschluss des (separaten) Bus-/Netzankopplers siehe
    Anschlusspläne.
    [A] Busankoppler;
    [B] Netzankoppler
    Hinweis
    A
    uf korrekte Polarität achten.
    Inbetriebnahme
    Über die Inbetriebnahmesoftware ETS (ETS 3.0 f mit Power Tool
    bzw. ab ETS 4.0 ohne Zusatzsoftware) können verschiedene
    Funktionen realisiert werden. Die Funktion ist abhängig von den über
    die jeweilige Softwareapplikation gewählten Parametern.
    Detaillierte Inbetriebnahme- und Parameterbeschreibung siehe
    Technisches Handbuch (siehe QR-Code).
    Bedienung
    Frontalansicht
    [A] ECO-Taste
    [B] Beschriftungsfeld
    [C] Menü-Taste
    [D] Sollwertverstellung
    [E] LED
    [F] Display
    [G] Umschaltaste
    Die Bedienung des Raumtemperaturreglers erfolgt über die Tasten
    [A + C + D] unterhalb des Displays .
    Die Umschaltung in die Menüebene erfolgt über die Zusatztaste [G]
    neben dem Display.
    Displayanzeigen / Meldungen
    A Komfort-Betrieb:
    Heizung/Kühlung auf Normalniveau
    Nur sichtbar, wenn „Betriebsmodus überlagert“ aktiv
    (Vor-Ort-Bedienung gesperrt).
    B Standby-Betrieb:
    Heizungs-/Kühlungsleistung wird leicht gesenkt
    C Taupunkt-Betrieb:
    Raumtemperatur wird nicht weiter gesenkt
    D Frostschutz-Betrieb
    Temperatur wird über einem Mindestwert gehalten.
    E Hitzeschutz-Betrieb
    Temperatur wird unter einem Maximalwert gehalten.
    F Kondensat
    Der Kondenswasserbehälter ist voll. Das Gerät arbeitet im
    Hitzeschutzbetrieb.
    G AUS
    Die Regelung ist ausgeschaltet. Das Gerät arbeitet im
    Frostschutzbetrieb.
    H ECO-Mode:
    Heizungs-/Kühlungsleistung wird stark gesenkt
    I Umschaltung Heizen/Kühlen
    Umschaltung manuell
    J Lüfterstufen 1-4:
    Lüftungssteuerung manuell
    K Lüfterstufen Automatisch:
    Lüftungssteuerung automatisch
    Service
    Busch-Jaeger Elektro GmbH - Ein Unternehmen der ABB Gruppe,
    Freisenbergstraße 2, D-58513 Lüdenscheid,
    Tel: +49 2351 956-1600; www.BUSCH-JAEGER.de
    Pos: 5 /Faltblatt 35x42/KNX/Installationsbus/6128/6128 @ 43\mod_1438424178138_15.docx @ 370924 @ 11222222222 @ 1
    English
    Busch-Installationsbus
    ®
    KNX,
    Busch-Powernet
    ®
    KNX
    Control element, 2/4gang with room
    temperature controller
    Danger
    Dangerous currents flow through the body when coming
    into direct or indirect contact with live components. This
    can result in electric shock, burns or even death. Work
    improperly carried out on current-carrying parts can cause
    fires.
    Disconnect the mains power supply prior to installation
    and/or disassembly!
    Permit work on the 230 V supply system to be
    performed only by specialist staff.
    Please read the mounting instructions carefully and keep them for
    future use.
    Additional user information and information for parameter setting
    and commissioning is available at www.BUSCH-JAEGER.de or
    by scanning the QR code.
    Intended use
    The room temperature controller is suitable for the control of a fan
    convector with fan-coil actuator or a conventional heating and cooling
    system.
    Extensive functions are available for the control elements. The range
    of applications is available in the technical reference manual (DE, EN,
    FR, IT, NL, ES) on the product.
    Technical data
    Power supply
    Bus coupler: 24 V DC (via bus line)
    Network coupler: 230 V AC / 50 Hz
    Bus subscribers: Maximum 12 mA
    KNX connection:
    Bus coupler: Bus connecting terminal, screwless
    Network coupler: Screw terminals on the flush-mounted
    insert
    Temperature range: -5°C - +45°C
    Protection type: IP20
    Storage temperature: -20°C - +70°C
    Other features
    Theft protection
    Day/Night switchover of LEDs
    Labelling possible
    Mounting
    [1a …d]
    Mounting only in dry interior rooms on a flush-mounted
    bus/network coupler, which is to be ordered separately.
    Observe the currently valid regulations.
    Observe the installation instructions.
    Please order the cover frame separately.
    [2] The rockers have twist protection (lower web is wider) to ensure
    that they are attached the right way around.
    [3] The protective cover of the labelling field can be removed.
    To insert it, observe the above illustration.
    Connection
    For the connection of the (separate) bus / network coupler, see the
    connecting diagrams.
    [A] Bus coupler;
    [B] Network coupler
    NOTE
    Observe correct polarity.
    Commissioning
    Various functions can be implemented via the ETS commissioning
    software (ETS 3.0 f with Power-Tool or from ETS 4.0 without
    additional software). The function is dependent on the parameters
    selected via the respective software application.
    For a detailed description of commissioning and parameters, see the
    technical reference manual (see QR code).
    Operation
    Frontal view
    [A] ECO button
    [B] Labelling field
    [C] Menu button
    [D] Setpoint adjustment
    [E] LED
    [F] Display
    [G] Switchover button
    The room temperature controller is operated via buttons [A + C + D]
    beneath the display.
    The additional button [G] next to the display is used for switching over
    to the menu level.
    Displays / messages
    A Comfort mode:
    Heating/cooling at normal level
    Only visible when "Superimposed operating mode" is
    active (local operation is blocked).
    B Standby operation:
    Heating/cooling output is slightly lowered
    C Dew point mode:
    Room temperature in not lowered any further
    D Frost protection mode
    The temperature is kept above a minimum value.
    E Heat protection mode
    The temperature is kept below a maximum value.
    F Condensate
    The condensate tank is full. The device operates in heat
    protection mode.
    H OFF
    The control is deactivated. The device operates in frost
    protection mode.
    H ECO mode:
    Heating/cooling output is extremely lowered
    I Switchover heating/cooling
    Manual switchover
    J Fan speed levels 1-4:
    Manual ventilation control
    K Automatic fan speed levels:
    Automatic ventilation control
    Service
    Busch-Jaeger Elektro GmbH - A member of the ABB Group,
    Freisenbergstraße 2, D-58513 Lüdenscheid, Germany, Tel: +49 2351
    956-1600; www.BUSCH-JAEGER.de
    Pos: 6 /Systemmodule/++++++++++++++ Seitenumbruch +++++++++++++++ @ 41\mod_1422789416992_0.docx @ 333485 @ @ 1
Busch-Jaeger 2CKA006134A0324

Hulp nodig?

Aantal vragen: 0

Heeft u een vraag over de Busch-Jaeger 2CKA006134A0324 of heeft u hulp nodig? Stel hier je vraag. Zorg voor een duidelijke en uitgebreide omschrijving van het probleem en je vraag. Hoe beter je probleem en vraag is omschreven, hoe makkelijker het is voor andere Busch-Jaeger 2CKA006134A0324 bezitters om je van een goed antwoord te voorzien.

Bekijk hier gratis de handleiding van de Busch-Jaeger 2CKA006134A0324. Deze handleiding valt onder de categorie Niet gecategoriseerd en is door 1 mensen gewaardeerd met een gemiddelde van een 8.8. Deze handleiding is beschikbaar in de volgende talen: Nederlands, Engels, Duits. Heeft u een vraag over de Busch-Jaeger 2CKA006134A0324 of heeft u hulp nodig? Stel hier je vraag

Busch-Jaeger 2CKA006134A0324 specificaties

Algemeen
Merk Busch-Jaeger
Model 2CKA006134A0324
Product Niet gecategoriseerd
Taal Nederlands, Engels, Duits
Bestandstype PDF
Kenmerken
Producttype Thermostatische actor
Ingebouwd display
Internationale veiligheidscode (IP) IP20
Kleur van het product Wit
Compatibele producten Busch-Jaeger 6120/13, 6120/12-101
Certificering RoHS
CE
drukknop
LED-indicatoren
Gewicht en omvang
Breedte 63mm
Hoogte 63mm
Eisen aan de omgeving
Temperatuur, in bedrijf -5 - 45°C
Temperatuur bij opslag -20 - 70°C
Energie
Ingangsspanning 230V
Frequentie 50Hz

Handleidi.ng

Op zoek naar een handleiding? Handleidi.ng zorgt er voor dat je binnen no-time de handleiding vindt die je zoekt. In onze database zitten meer dan 1 miljoen PDF handleidingen van meer dan 10.000 merken. Elke dag voegen wij de nieuwste handleidingen toe zodat je altijd het product zal vinden wat je zoekt. Het is heel eenvoudig: typ in de zoekbalk de merknaam en het type product en je kan direct de handleiding van je keuze gratis online bekijken.

Handleidi.ng

© Copyright 2020 Handleidi.ng. Alle rechten voorbehouden.

We gebruiken cookies om er zeker van te zijn dat je onze website zo goed mogelijk beleeft. Als je deze website blijft gebruiken gaan we ervan uit dat je dat goed vindt.

Meer info